Differential Dome-Loaded Pressure Reducing Regulator 1.5"
High Performance Pressure Reducing Regulator designed for use in the natural gas industry but equally applicable to other inert gases. The Differential Dome-Load design allows for a more stable regulated pressure range and is less susceptible to fluctuation. The differential sensing piston allows for better performance with a decaying inlet pressure, such as when emptying a tube trailer i.e. PRS service. Extra-large Ports allow for extra flow and removable lower cap and shuttle mounted seat allows for in-place servicing.
Competitively priced service kits.
Performance:
- Outlet pressure 15 – 5000psi
- Max Inlet pressure 5000 psi (350 bar)
- CV (flow) 12.7
Port Configuration:
- Inlet 1½” NPT
- Outlet 1½” NPT
- Control ports ¼” NPT
Standard Specifications:
- Nominal Bore 1¼” 32mm
- Weight 8.4kg (no tubing or pilot)
- Filtration requirement 20 micron (not supplied)
- Temperature range -30°C to 85°C